Performing an ultrasound examination with the GE Vivid 7 machine is not
any more difficult than using any other scanner machine—yet using the GE
Vivid 7 can give doctors and technicians quite a bit more when it comes
to results. First of all, the GE Vivid 7 ultrasound machine has
tri-plane imaging—and, it was the first machine to introduce this
technology. This means that it can take three images of the same
heartbeat. This can be quite helpful for real-time assessment of heart
conditions. The GE Vivid 7 also does real-time 4-D imaging, which
provides more information about tissue structure and function.
Blood-flow imaging is also a feature of the GE Vivid 7. This type of
imaging allows doctors and technicians to see exactly how a patient’s
blood is flowing. The advanced technology and imaging techniques of the
GE Vivid 7 make it a good choice for any medical establishment.
Imaging Modes
- Real-time Anatomical M-mode
- Tissue Tracking Imaging
- Quantitative Tissue Velocity Imaging
- Doppler
- Color Flow
- 2D Image
- Coded Octave Harmonic
- PW Spectral Doppler
- CW Spectral Doppler
Features
- Better image quality for 2D, Doppler and color flow imaging
- Uncomplicated quantification of LV function
- Raw data DICOM connectivity in system that is easy to operate in clinical settings
- 4D cardiology applications
- STRAIN
Transducers
- M3S 1.5 -4.0 MHz, Adult Cardiac/Transcranial TCD Phased Array Sector
- 3V 3D/4D cardiac Sector
- 3S 1.5-3.6 MHz, Cardiac Phased Array Sector
- 5S 2.2 -5.0 MHz, High Resolution Adult Cardiac Phased Array Sector
- 7S 3.5-8.0 MHz, Pediatric Cardiac Phased Array Sector
- 10S H4901PC, 4.4-10.0 MHz, Neonatal Cardiac Phased Array Sector
- H4830JE, 2.0 MHz, Doppler
- H4830JG, 6.0 MHz, Doppler
- 3.5C 2.4-4.5 MHz, Abdominal Convex Array
- 8C 5.0-8.0 MHz Abdominal, Vascular, Neonatal Head Convex Array
- M7C 5.0-7.0 MHz Abdominal and Vascular Convex Array
- 5C 4.4-6.7 MHz High Frequency Abdominal and Vascular Convex Array
- E8C 5.0-8.0 Mhz Endovaginal Convex Array
- M12L 5.6-14.0 MHz Small Parts Linear Array
- 12L 5.2-13.0 MHz Small Parts Linear Array
- 10L 4.8-10 MHz Peripheral Vascular Linear Array
- 7L 3.3-8.0 MHz Peripheral and Cerebro Vascular Linear Array
- i13L 10.0-14.0 MHz Intraoperative Linear Array
- i8L 6.0-10.0 MHz Intraoperative Linear Array
- 6T 2.9-7.0 MHz, Phased Array Multiplane Transesophageal
- 9T 4.0-10 MHz, Phased Array Multiplane Transesophageal
- Pencil probe P2D (2 mhz)
- Pencil probe P6D (5/5.8 mhz)